System Design and Analysis of Heat Supply Using Waste Heat from Data Centers

Waste heat heating in data centers is an important way to improve the energy utilization efficiency of data centers and achieve clean heating in winter. This paper proposes a long-distance heating system for data centers, setting up a multi-stage heat pump at the heat source and heat sink to increase the temperature difference between the supply and return water of the heating pipeline network, and using a heat storage device to guarantee the safety of the data center and the heating system, and to improve the utilization rate of waste heat in the data center. A data center in Zhangjiakou was analyzed as an example, and the initial investment of the system is 50.21 yuan/m2, the operating cost is 26.37 yuan/GJ, and the payback period is about 5.31 a, which has better economy and energy saving and emission reduction effect.
READ MORE
date:2024-10-23

Air conditioning heat pump dichotomous supply

To put it simply, the so-called “two-connected supply” is to use a set of air energy heat pump system to provide “hot water + heating” or “heating + cooling” two combinations of functions; The “triple-heating” is to provide “air conditioning + floor heating + hot water” three combinations of functions. The terms “two-connected supply” and “three-connected supply” generally refer to hot and cold water air-conditioning systems.
READ MORE
date:2024-10-21

Double 11 superimposed on home appliances “national subsidies”, TCL small blue wing P7 air conditioning to take care of the health of the family

Healthy wind intelligent guarding, easy to deal with seasonal discomfort
READ MORE
date:2024-10-18

Analysis of economizer application under compression refrigeration cycle

Therefore, the economizer screw refrigeration cycle system is firstly studied a lot and widely applied under low temperature working condition.
READ MORE
date:2024-10-16

Selection of cold water pump

aircondition unit
airconditioning units
split ac stand
refrigerated truck body
one way cassette air conditioner
heat pump for home
industrial ac
Usually choose the centrifugal water pump with a rotational speed of 30~150 revolutions per second, and the flow rate of the pump should be 1.1~1.2 times of the rated flow rate of the chiller (1.1 for a single unit and 1.2 for two units working in parallel).
READ MORE
date:2024-10-15

Research on Indoor Thermal Environment and Human Thermal Comfort in Office Buildings with Different Heating Ends

Radiant heating; convective heating; office building; indoor thermal environment; thermal comfort; neutral temperature; acceptable temperature; field study
READ MORE
date:2024-10-14
Prev 10 11 12 13 14 15 16 17 18 19 Next